SDMC TMP-3T Manuale Utente

Navigare online o scaricare Manuale Utente per Software SDMC TMP-3T. SDMC TMP-3T Product data Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 436
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
ibm.com/redbooks
IBM Systems Director
Management Console
Introduction and Overview
Thomas Libor, PhD
Allen Oh
Lakshmikanthan Selvarajan
Peter Wuestefeld
Documents the SDMC appliance, which
uses the Systems Director user interface
Discusses the differences
between the HMC and SDMC
Provides a practical guide to
the SDMC
Front cover
Vedere la pagina 0
1 2 3 4 5 6 ... 435 436

Sommario

Pagina 1 - Management Console

ibm.com/redbooksIBM Systems Director Management ConsoleIntroduction and OverviewThomas Libor, PhDAllen OhLakshmikanthan SelvarajanPeter WuestefeldDocu

Pagina 2

viii IBM Systems Director Management Console: Introduction and Overview14.5.2 Support Files Management . . . . . . . . . . . . . . . . . . . . . . .

Pagina 3 - April 2011

74 IBM Systems Director Management Console: Introduction and OverviewFor the second method, perform the following steps to perform a transition of th

Pagina 4

© Copyright IBM Corp. 2011. All rights reserved. 75Chapter 5. System managementThis chapter contains information about how to discover managed systems

Pagina 5

76 IBM Systems Director Management Console: Introduction and Overview5.1 System discoveryDiscovery is the process by which IBM Systems Director iden

Pagina 6

Chapter 5. System management 77You can launch the System Discovery tool by selecting the Common Tasks menu in the Welcome page or by clicking the Sy

Pagina 7

78 IBM Systems Director Management Console: Introduction and OverviewVerify Connection pageThe Verify Connection page validates the connection betwee

Pagina 8

Chapter 5. System management 79Request Access pageUse the Request Access page to request access to a system to which your SDMC has not yet authentic

Pagina 9

80 IBM Systems Director Management Console: Introduction and OverviewConfigure Access pageUse the Configure Access page to view the status of Remote

Pagina 10

Chapter 5. System management 815.1.2 Discovery of POWER processor-based bladesA POWER processor-based blade can be managed in very much the same wa

Pagina 11

82 IBM Systems Director Management Console: Introduction and OverviewThe blade servers discovered directly and the blade servers that are discovered

Pagina 12

Chapter 5. System management 83The DHCP service starts after the SDMC installation is completed. You can also manually start or stop the DHCP servic

Pagina 13 - Figures xi

© Copyright IBM Corp. 2011. All rights reserved. ixFigures1-1 HMC and IVM management of POWER servers . . . . . . . . . . . . . . . . . . . . 21-2

Pagina 14

84 IBM Systems Director Management Console: Introduction and Overview5.2 System discovery using the HMCYou can also discover and manage systems that

Pagina 15 - Figures xiii

Chapter 5. System management 85The context menu is shown in Figure 5-4.Figure 5-4 Extended managementSDMC does not directly manage the systems con

Pagina 16

86 IBM Systems Director Management Console: Introduction and OverviewIf you want to list the systems on the SDMC that are being directly managed, use

Pagina 17

Chapter 5. System management 87Figure 5-5 Edit Host page5.3.2 Operations pageThe Operations page includes the tasks for server operations. Right-

Pagina 18

88 IBM Systems Director Management Console: Introduction and OverviewThe tasks are available based on the current operating state of the managed syst

Pagina 19 - Examples

Chapter 5. System management 895.3.6 Release Management pageThe Release Management page includes tasks for updating the firmware level of the manag

Pagina 20

90 IBM Systems Director Management Console: Introduction and OverviewThe tasks are explained in detail in Chapter 14, “Service and support” on page 3

Pagina 21

Chapter 5. System management 915.4 Hierarchical managementHierarchical management is a feature available in IBM Systems Director that enables you t

Pagina 22 - Trademarks

92 IBM Systems Director Management Console: Introduction and Overview5.4.1 Enabling hierarchical managementTo enable hierarchical management on the

Pagina 23

Chapter 5. System management 933. Discover the domain server (another SDMC that is connected to managed systems) from the System Discovery page. The

Pagina 24 - The team who wrote this book

x IBM Systems Director Management Console: Introduction and Overview6-1 Available Power Units . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 25 - Comments welcome

94 IBM Systems Director Management Console: Introduction and Overview5.5 Capacity on DemandCapacity on Demand (CoD) offerings allow you to dynamical

Pagina 26

Chapter 5. System management 95Right-click the managed system and select System Configuration  Capacity on Demand (CoD) to launch the CoD page. The

Pagina 27 - Overview

96 IBM Systems Director Management Console: Introduction and OverviewProcessor Settings and Memory Settings are hyperlinks and clicking any of them t

Pagina 28 - Private Mgmt Network II

Chapter 5. System management 975.5.4 CoD operationsYou can perform all CoD related operations from the CoD page. These operations are exactly the s

Pagina 29 - Console

98 IBM Systems Director Management Console: Introduction and Overview

Pagina 30 - Management

© Copyright IBM Corp. 2011. All rights reserved. 99Chapter 6. Power Unit managementThis chapter describes how the IBM Systems Director Management Cons

Pagina 31 - Chapter 1. Overview 5

100 IBM Systems Director Management Console: Introduction and Overview6.1 Power Unit managmentWhen a host is discovered, so are the Power Units. The

Pagina 32

Chapter 6. Power Unit management 1016.1.1 Edit Power Unit pageYou can view and edit the properties of a Power Unit using the Edit Power Unit page.

Pagina 33 - Chapter 1. Overview 7

102 IBM Systems Director Management Console: Introduction and Overview6.1.2 Bulk Power Assembly (BPA) Status pageYou can view the state of the conne

Pagina 34

Chapter 6. Power Unit management 103You have to enter the current password, then a new password, and verify it by entering it again.If you change th

Pagina 35

Figures xi8-17 Create Virtual Server: Optical device and media selection . . . . . . . . . . 1498-18 Create Virtual Server: Load Source and Consol

Pagina 36 - 1.6 Functional differences

104 IBM Systems Director Management Console: Introduction and Overview6.1.5 Launch Advanced System Management pageYou can open the Advanced System M

Pagina 37 - 1.6.2 Users and roles

Chapter 6. Power Unit management 105Rebuilding, or recreating, the managed frame acts much like a refresh of the frame information. Rebuilding a fra

Pagina 38 - 1.6.6 Backup and restore

106 IBM Systems Director Management Console: Introduction and Overview

Pagina 39 - 1.6.7 SDMC considerations

© Copyright IBM Corp. 2011. All rights reserved. 107Chapter 7. Firmware updatesThis chapter cover installing and managing firmware on Power Systems fr

Pagina 40

108 IBM Systems Director Management Console: Introduction and Overview7.1 Update ManagerThe Update Manager is the component of SDMC used to perform

Pagina 41 - Installation

Chapter 7. Firmware updates 109Chapter 10, “Update Manager”, in Implementing IBM Systems Director 6.1, SG24-7694.In this chapter, we focus on only t

Pagina 42 - 2.1 Prerequisites

110 IBM Systems Director Management Console: Introduction and Overview7.1.1 Readiness Check pageBefore performing any of the installation or managem

Pagina 43 -

Chapter 7. Firmware updates 111Click the Gather Target Information button on the Readiness Check page to run the Readiness Check on the target syste

Pagina 44

112 IBM Systems Director Management Console: Introduction and OverviewIf the selected system pass the Readiness Check, the Readiness column shows as

Pagina 45

Chapter 7. Firmware updates 113򐂰 SDMC requires more update files for an image than just the .xml and .rpm files; it also requires the .dd.xml, .pd.s

Pagina 46

xii IBM Systems Director Management Console: Introduction and Overview8-60 Select Validate from the partition page . . . . . . . . . . . . . . . . .

Pagina 47

114 IBM Systems Director Management Console: Introduction and OverviewGetting updatesThe easiest way to check for and download the latest updates is

Pagina 48

Chapter 7. Firmware updates 115The user can then select the type of updates to check for on the Check for Updates page (Figure 7-7) and continue thr

Pagina 49

116 IBM Systems Director Management Console: Introduction and OverviewThe updates for any IBM hardware managed by the SDMC (including Power Systems a

Pagina 50

Chapter 7. Firmware updates 117If the USB is formatted for a vFAT file system, run the following command:mount -t vfat /dev/sda1 /mnt/usbThe simples

Pagina 51

118 IBM Systems Director Management Console: Introduction and OverviewIn the same Common tasks section, there is also a link for Import Updates by FT

Pagina 52

Chapter 7. Firmware updates 119Updating target systemsOn the Update Manager page, you can start an installation from the Show needed updates, Show a

Pagina 53

120 IBM Systems Director Management Console: Introduction and OverviewTo update the target systems, perform the following steps:1. To install the lat

Pagina 54

Chapter 7. Firmware updates 1212. The Show Needed Updates page opens and show the system(s) from the selected list. Click the Show Needed Updates bu

Pagina 55

122 IBM Systems Director Management Console: Introduction and OverviewAlso note the error message that appears at the top of the page stating that an

Pagina 56

Chapter 7. Firmware updates 1234. On the Systems page that opens (Figure 7-14), select the target system to which you want to apply the previously s

Pagina 57

Figures xiii9-42 Snapshot manager . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2619-43 View Trace Logs . . . .

Pagina 58

124 IBM Systems Director Management Console: Introduction and Overview5. The Options page shows any applicable installation options or any additional

Pagina 59

Chapter 7. Firmware updates 1256. From the Start Target Checks page, initiate readiness and concurrency checks for the selected targets. These check

Pagina 60

126 IBM Systems Director Management Console: Introduction and Overview7.1.3 Power Firmware Management tasksYou can manage firmware on Power Systems

Pagina 61

Chapter 7. Firmware updates 127Procedures for Power Firmware Management operationsFrom the Resources tab on the Welcome page on the SDMC GUI, perfor

Pagina 62

128 IBM Systems Director Management Console: Introduction and OverviewThe Power Firmware Management page opens (Figure 7-18). As with the readiness c

Pagina 63

Chapter 7. Firmware updates 1292. After the target information is gathered, the Accept/Reject, Disruptive Activate, Synchronize, Remove and Activate

Pagina 64

130 IBM Systems Director Management Console: Introduction and Overview3. Click the Start Accept Task button (Figure 7-20).Figure 7-20 Start Accept

Pagina 65

© Copyright IBM Corp. 2011. All rights reserved. 131Chapter 8. Virtual Server operationThe Virtual Server operation contains the operations for Virtua

Pagina 66

132 IBM Systems Director Management Console: Introduction and Overview8.1 Virtual Server creationOn the Hardware Management Console, Virtual Servers

Pagina 67

Chapter 8. Virtual Server operation 133To create a Virtual Server, perform the following steps:1. From the Welcome page, locate the host on which th

Pagina 68

xiv IBM Systems Director Management Console: Introduction and Overview14-14 Manage Support Files system wide view . . . . . . . . . . . . . . . . .

Pagina 69

134 IBM Systems Director Management Console: Introduction and OverviewFigure 8-2 shows the wizard that allows you to create a Virtual Server.2. On th

Pagina 70

Chapter 8. Virtual Server operation 1353. When you are creating a Virtual Server for the Virtual I/O Server environment type, some selections will b

Pagina 71

136 IBM Systems Director Management Console: Introduction and Overview4. To create IBM i Virtual Servers, use the Memory menu (Figure 8-4). The diffe

Pagina 72

Chapter 8. Virtual Server operation 1375. The assigned memory can be dedicated or shared (Figure 8-5). The Shared option needs the Active Memory Sha

Pagina 73

138 IBM Systems Director Management Console: Introduction and Overview6. As shown in Figure 8-6, the default processor mode for Virtual Servers is Sh

Pagina 74

Chapter 8. Virtual Server operation 1397. As shown in Figure 8-7, the wizard queries the available Ethernet connections of the Virtual I/O Servers.

Pagina 75

140 IBM Systems Director Management Console: Introduction and OverviewIf you would like to add a Logical Host Ethernet Adapter port to the partition,

Pagina 76

Chapter 8. Virtual Server operation 141The ability to add storage adapters automatically when creating a Virtual Server was added to provide legacy

Pagina 77

142 IBM Systems Director Management Console: Introduction and OverviewFigure 8-10 Create Virtual Server: Assign storage adapter IDs

Pagina 78

Chapter 8. Virtual Server operation 14310.The results are shown in Figure 8-11. If you decide to add another adapter to a second Virtual I/O Server,

Pagina 79

© Copyright IBM Corp. 2011. All rights reserved. xvTables1-1 Server firmware support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 80

144 IBM Systems Director Management Console: Introduction and Overview11.If automatic storage adapter creation is chosen (Figure 8-12), additional ch

Pagina 81

Chapter 8. Virtual Server operation 14512.Click Next. The page shown in Figure 8-13 opens. Clicking the Create Virtual Disk button opens a page wher

Pagina 82

146 IBM Systems Director Management Console: Introduction and OverviewAs shown in Figure 8-14, the Virtual I/O Server, the name, the disk pool and th

Pagina 83

Chapter 8. Virtual Server operation 14713.If automatic storage adapter creation for Physical Disks was checked, you can select available disks in al

Pagina 84

148 IBM Systems Director Management Console: Introduction and Overview14.If you select Fibre Channel in the page shown in Figure 8-16, then, on the S

Pagina 85

Chapter 8. Virtual Server operation 14915.In Figure 8-17, you can select either physical or virtual optical media. A virtual optical device is chose

Pagina 86

150 IBM Systems Director Management Console: Introduction and Overview16.If you created an IBM i Virtual Server, an additional page is available befo

Pagina 87

Chapter 8. Virtual Server operation 15117.The last page in the Create Virtual Server Wizard, the Physical I/O Adapters page, allows you to attach ph

Pagina 88

152 IBM Systems Director Management Console: Introduction and OverviewExample 8-1 is a sample command that is used to create an Virtual Server.Exampl

Pagina 89

Chapter 8. Virtual Server operation 153To activate a Virtual Server, perform the following steps:1. Right-click the server name and select Operation

Pagina 90

xvi IBM Systems Director Management Console: Introduction and OverviewA-19 listjobs command . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 91

154 IBM Systems Director Management Console: Introduction and Overview2. Select a profile. In our example, we only have the default profile, which is

Pagina 92

Chapter 8. Virtual Server operation 1553. Click the Advanced tab and select the options for the keylock position and boot mode (Figure 8-22).Figure

Pagina 93

156 IBM Systems Director Management Console: Introduction and Overview4. The Welcome page opens and shows the state and detailed state of the Virtual

Pagina 94

Chapter 8. Virtual Server operation 1578.3 Virtual Server shutdownTo shut down a Virtual Server, navigate to the Welcome page, right-click the name

Pagina 95

158 IBM Systems Director Management Console: Introduction and OverviewThe next page (Figure 8-25) shows the available options for shutting down the o

Pagina 96

Chapter 8. Virtual Server operation 1598.4 Virtual Server managementThe Manage Virtual Server menu option in the Welcome page allows you to customi

Pagina 97

160 IBM Systems Director Management Console: Introduction and OverviewTo manage the Virtual Server, navigate to the Welcome page, right-click the nam

Pagina 98

Chapter 8. Virtual Server operation 161The page with the General Settings tab opens (Figure 8-27). The settings that can be changed here are shown i

Pagina 99

162 IBM Systems Director Management Console: Introduction and OverviewThe Tasks button (Figure 8-28) allows you to execute the following tasks direct

Pagina 100

Chapter 8. Virtual Server operation 163The Processor page allows you to change the processor related settings of the Virtual Server, including the p

Pagina 101 - System management

© Copyright IBM Corp. 2011. All rights reserved. xviiExamples2-1 OVF Tool CLI using an OVA file on Windows. . . . . . . . . . . . . . . . . . . . . .

Pagina 102 - 5.1 System discovery

164 IBM Systems Director Management Console: Introduction and OverviewNote the blue values in the drop-down menu and the changed appearance of the bu

Pagina 103

Chapter 8. Virtual Server operation 165The default memory mode for Virtual Servers is Dedicated and Active Memory Expansion (AME) is enabled by defa

Pagina 104 - Verify Connection page

166 IBM Systems Director Management Console: Introduction and OverviewIf the memory mode is set to Shared, as shown in Figure 8-32, Advanced Memory S

Pagina 105 - Request Access page

Chapter 8. Virtual Server operation 167On the following Network tab (Figure 8-33), you can configure virtual network adapters for the Virtual Server

Pagina 106 - Revoke Access page

168 IBM Systems Director Management Console: Introduction and OverviewIf the check box right to the virtual network adapter is checked, the Edit butt

Pagina 107

Chapter 8. Virtual Server operation 169On the Storage Adapters page (Figure 8-35), you can removed existing storage adapters if you check the check

Pagina 108 - 5.1.4 Auto discovery

170 IBM Systems Director Management Console: Introduction and OverviewTo add an storage adapter, click the Add button (Figure 8-35 on page 169) and e

Pagina 109 - 5.1.5 IP address rules

Chapter 8. Virtual Server operation 171If you chose to add a Virtual Fibre Channel adapter, the page shown in Figure 8-37 opens. Note that the World

Pagina 110

172 IBM Systems Director Management Console: Introduction and OverviewOn the Storage Devices page (Figure 8-38), three types of storage devices can b

Pagina 111

Chapter 8. Virtual Server operation 173Figure 8-39 shows the available physical volumes on the Virtual I/O servers. We select hdisk8 on the second V

Pagina 113 - 5.3.2 Operations page

xviii IBM Systems Director Management Console: Introduction and Overview

Pagina 114 - 5.3.5 Hardware page

174 IBM Systems Director Management Console: Introduction and OverviewThe Add Fibre Channel menu allows you to add additional Virtual Fibre Channel a

Pagina 115

Chapter 8. Virtual Server operation 175The Media Devices page lets you add media devices to the Virtual Server, that is optical devices, such as CD

Pagina 116

176 IBM Systems Director Management Console: Introduction and OverviewFigure 8-42 shows the available Physical Media devices. Click the OK button to

Pagina 117 - 5.4 Hierarchical management

Chapter 8. Virtual Server operation 177Clicking Add in the Virtual Media section of the Media Devices page opens a list of the available virtual med

Pagina 118

178 IBM Systems Director Management Console: Introduction and OverviewThe task in Figure 8-43 on page 177 creates a Virtual Optical device adapter th

Pagina 119

Chapter 8. Virtual Server operation 179The last page in Manage Virtual Servers (Figure 8-45) allows you to add physical adapters to the Virtual Serv

Pagina 120 - 5.5 Capacity on Demand

180 IBM Systems Director Management Console: Introduction and OverviewIf you click the Add button, the list of physical adapters on the server appear

Pagina 121 - 5.5.2 Capacity on Demand

Chapter 8. Virtual Server operation 181When adding the physical adapters and virtual adapters, there is a short period of time where the addition of

Pagina 122 - 5.5.3 Advanced Functions

182 IBM Systems Director Management Console: Introduction and Overview8.4.1 Command-line usageChanges to the Virtual Server configuration also can b

Pagina 123 - 5.5.4 CoD operations

Chapter 8. Virtual Server operation 183On the Welcome page, navigate to the Virtual Server and right-click the Virtual Server to access the menu opt

Pagina 124

© Copyright IBM Corp. 2011. All rights reserved. xixNoticesThis information was developed for products and services offered in the U.S.A. IBM may not

Pagina 125 - Power Unit management

184 IBM Systems Director Management Console: Introduction and OverviewClicking Save Current Configuration takes you to the Save page (Figure 8-49). H

Pagina 126 - 6.1 Power Unit managment

Chapter 8. Virtual Server operation 1858.4.3 Virtual Server ProfilesThe Virtual Server Profile contains the configuration of the Virtual Server. Wh

Pagina 127 - 6.1.1 Edit Power Unit page

186 IBM Systems Director Management Console: Introduction and OverviewRemember that the display of menus is context sensitive and shows only tasks an

Pagina 128 - 6.1.3 Change Password page

Chapter 8. Virtual Server operation 187To access the profiles of a Virtual Server, refer to Figure 8-48 on page 183. Select System Configuration  M

Pagina 129 - 6.1.4 Initialize Frame page

188 IBM Systems Director Management Console: Introduction and OverviewClick Edit to open the Logical Partition Profile Properties menu. This menu all

Pagina 130 - 6.1.7 Rebuild page

Chapter 8. Virtual Server operation 189There are initially no System Profiles defined for a server. To create a System Profile, enter a name into th

Pagina 131

190 IBM Systems Director Management Console: Introduction and OverviewExpand the toggle of the Virtual Server to see all the profiles of that Virtual

Pagina 132

Chapter 8. Virtual Server operation 191Note that Virtual Servers using shared memory cannot be added to a system profile. If you attempt to add thes

Pagina 133 - Firmware updates

192 IBM Systems Director Management Console: Introduction and OverviewCommand-line usageA System Profile can also be defined by running smcli mksyscf

Pagina 134 - 7.1 Update Manager

Chapter 8. Virtual Server operation 1938.5.1 Suspend a Virtual ServerTo perform a suspend operation on an Virtual Server, perform the following ste

Pagina 135

xx IBM Systems Director Management Console: Introduction and OverviewTrademarksIBM, the IBM logo, and ibm.com are trademarks or registered trademarks

Pagina 136 - 7.1.1 Readiness Check page

194 IBM Systems Director Management Console: Introduction and Overview2. From the Partition Suspend/Resume page (Figure 8-59), you can select Suspend

Pagina 137

Chapter 8. Virtual Server operation 195The Resume status page shows the progress of the resume operation and shows a success completion.8.6 Mobilit

Pagina 138 - 7.1.2 Installing updates

196 IBM Systems Director Management Console: Introduction and Overview2. In the Validate page, the Migrate and View VLAN buttons should be currently

Pagina 139

© Copyright IBM Corp. 2011. All rights reserved. 197Chapter 9. IBM Systems Director Management Console managementThis chapter covers the various tasks

Pagina 140 - Getting updates

198 IBM Systems Director Management Console: Introduction and Overview9.1 User management and securityVirtualization means that more than one system

Pagina 141

Chapter 9. IBM Systems Director Management Console management 199Because the terminology and the structure of user and security management changes f

Pagina 142

200 IBM Systems Director Management Console: Introduction and Overview9.1.2 IBM Systems Director conceptsUsers in IBM Systems Director are users tha

Pagina 143

Chapter 9. IBM Systems Director Management Console management 201򐂰 sysadminThis is the user designed to be the primary administrator of the SDMC.򐂰 p

Pagina 144

202 IBM Systems Director Management Console: Introduction and OverviewUser groupsThe following user registry groups are employed for granting granula

Pagina 145 - Updating target systems

Chapter 9. IBM Systems Director Management Console management 203Refer to Figure 9-1 for a display of users and their initially assigned groups afte

Pagina 146

© Copyright IBM Corp. 2011. All rights reserved. xxiPrefaceThis IBM® Redbooks® publication positions the IBM Systems Director Management Console (SDMC

Pagina 147

204 IBM Systems Director Management Console: Introduction and Overview AssignedRoles: {'SMAdministrator' applied to <ALL GROUPS>}

Pagina 148

Chapter 9. IBM Systems Director Management Console management 205RolesThere are four roles that are initially defined on the SDMC:򐂰 SMAdministratorT

Pagina 149

206 IBM Systems Director Management Console: Introduction and OverviewCreating a roleTo create a role, perform the following steps:1. Expand Security

Pagina 150

Chapter 9. IBM Systems Director Management Console management 2072. Click Create to open the Roles wizard Welcome page. Clicking Next opens the Name

Pagina 151

208 IBM Systems Director Management Console: Introduction and Overview3. Clicking Next opens the Permissions page (Figure 9-4). You see a page with t

Pagina 152

Chapter 9. IBM Systems Director Management Console management 2094. Click the plus sign next to any role to expand it. All permissions collected in

Pagina 153

210 IBM Systems Director Management Console: Introduction and OverviewListing rolesRoles can be listed using the command line by running smcli lsrole

Pagina 154

Chapter 9. IBM Systems Director Management Console management 211GroupsThe concept of groups in the SDMC is equivalent to that of Resource Roles in

Pagina 155 - Figure 7-19 Accept

212 IBM Systems Director Management Console: Introduction and OverviewCreating a groupTo create a group, perform the following steps:1. Click Navigat

Pagina 156

Chapter 9. IBM Systems Director Management Console management 2132. Click Create Group to open the Welcome page of the Group Editor wizard (Figure 9

Pagina 157 - Virtual Server operation

xxii IBM Systems Director Management Console: Introduction and OverviewThe team who wrote this bookThis book was produced by a team of specialists fr

Pagina 158 - 8.1 Virtual Server creation

214 IBM Systems Director Management Console: Introduction and Overview3. Enter a name for the group and, optionally, a description on the Name page a

Pagina 159

Chapter 9. IBM Systems Director Management Console management 2154. Click Next to open the Define page, which allows for a wide selection of resourc

Pagina 160

216 IBM Systems Director Management Console: Introduction and Overview5. To select a single entry, for example, a Virtual Server, click All Systems.

Pagina 161

Chapter 9. IBM Systems Director Management Console management 2176. Click Next, and the Summary page that lists the resources assigned to this group

Pagina 162 - Source/Console pane

218 IBM Systems Director Management Console: Introduction and OverviewAfter clicking Finish, the wizard closes and the new group is shown on the Grou

Pagina 163

Chapter 9. IBM Systems Director Management Console management 219To assign a role to a user, perform the following steps:1. In the left pane of the

Pagina 164

220 IBM Systems Director Management Console: Introduction and Overview2. The Welcome page of the Assign Role wizard opens. Click Next to open the Rol

Pagina 165

Chapter 9. IBM Systems Director Management Console management 2213. Select the roles you want to assign to this user and click Next to open the Grou

Pagina 166

222 IBM Systems Director Management Console: Introduction and Overview4. Click Next to open the Summary page, which lists permissions and groups assi

Pagina 167

Chapter 9. IBM Systems Director Management Console management 223Authentication methodsThree different authentication methods can be used with SDMC.

Pagina 168

Preface xxiiiUdo SachsSVA GermanyNow you can become a published author, too!Here's an opportunity to spotlight your skills, grow your career, a

Pagina 169

224 IBM Systems Director Management Console: Introduction and OverviewLocal authenticationTo perform local authentication, perform the following step

Pagina 170

Chapter 9. IBM Systems Director Management Console management 2252. A page opens where the user credentials can be specified. Refer to Figure 9-19 f

Pagina 171

226 IBM Systems Director Management Console: Introduction and OverviewOptionally, you can specify a user description (Description), an SSH session ti

Pagina 172

Chapter 9. IBM Systems Director Management Console management 227򐂰 Users need only one user ID and password, as opposed to multiple accounts for eac

Pagina 173

228 IBM Systems Director Management Console: Introduction and Overview --bindpw password --loginattr uid --groupfilter '(|(objectclass=g

Pagina 174

Chapter 9. IBM Systems Director Management Console management 229Another method to configure SDMC for LDAP user management is by using a GUI. In the

Pagina 175

230 IBM Systems Director Management Console: Introduction and OverviewThe Welcome page of the LDAP client configuration wizard is shown in Figure 9-2

Pagina 176

Chapter 9. IBM Systems Director Management Console management 231Figure 9-22 shows how to create a user for LDAP authentication. No other informatio

Pagina 177 - Command-line usage

232 IBM Systems Director Management Console: Introduction and OverviewKerberosSDMC allows for Kerberos authentication. A detailed configuration walkt

Pagina 178

Chapter 9. IBM Systems Director Management Console management 233SDMC can be configured as a Kerberos client in the GUI by clicking the Configure Ke

Pagina 179

xxiv IBM Systems Director Management Console: Introduction and OverviewStay connected to IBM Redbooks򐂰 Find us on Facebook:http://www.facebook.com/IB

Pagina 180

234 IBM Systems Director Management Console: Introduction and OverviewAfter clicking the link, a wizard walks you through the required steps to compl

Pagina 181

Chapter 9. IBM Systems Director Management Console management 235After configuring the Kerberos client, a user can be added to the SDMC by clicking

Pagina 182

236 IBM Systems Director Management Console: Introduction and OverviewExample 9-12 provides an example about how to use the mkuser command with Kerbe

Pagina 183 - 8.3 Virtual Server shutdown

Chapter 9. IBM Systems Director Management Console management 237Modifying user propertiesAfter the new user account has been created, its propertie

Pagina 184

238 IBM Systems Director Management Console: Introduction and OverviewClick the newly created user to open the User properties page (Figure 9-27). In

Pagina 185

Chapter 9. IBM Systems Director Management Console management 239All of the listed attributes can be changed except the first two, which were define

Pagina 186 - Virtual Server (Figure 8-26)

240 IBM Systems Director Management Console: Introduction and OverviewDeleting usersTo remove a user using the command line, run smcli rmuser (Exampl

Pagina 187

Chapter 9. IBM Systems Director Management Console management 241To take advantage of the additional security and ease of setup, implement service n

Pagina 188

242 IBM Systems Director Management Console: Introduction and OverviewTo view and change the network settings go to the Settings tab on the Welcome p

Pagina 189

Chapter 9. IBM Systems Director Management Console management 243When you select it, the network configuration wizard starts (Figure 9-30).Figure 9-

Pagina 190

© Copyright IBM Corp. 2011. All rights reserved. 1Chapter 1. OverviewThe IBM Systems Director Management Console (SDMC) is the successor to the Hardwa

Pagina 191

244 IBM Systems Director Management Console: Introduction and OverviewDHCPIf you select Configure System as a DHCP server, you get a page where you c

Pagina 192

Chapter 9. IBM Systems Director Management Console management 245IP addressIf you select Standard network interface, you get a page where you can se

Pagina 193

246 IBM Systems Director Management Console: Introduction and OverviewFirewallAfter selecting a DHCP or static IP address, the Firewall menu opens, w

Pagina 194

Chapter 9. IBM Systems Director Management Console management 247IBM Systems Director Console HTTP Access8421:TCP NoCommon Agent Service(CAS) 9510:T

Pagina 195

248 IBM Systems Director Management Console: Introduction and OverviewAfter configuring the firewall, the LAN adapter page opens again, where you can

Pagina 196 - Figure 8-36

Chapter 9. IBM Systems Director Management Console management 249DNSIn the next page, you can specify one or more Domain Name Services (DNS) server

Pagina 197

250 IBM Systems Director Management Console: Introduction and OverviewNetwork reconfigurationIn the next page, a job is scheduled for the reconfigura

Pagina 198

Chapter 9. IBM Systems Director Management Console management 251You can close this page by clicking close. You can see the status of the job by sel

Pagina 199

252 IBM Systems Director Management Console: Introduction and Overview9.2.2 Configuring network settings using the SDMC CLIYou can also view and cha

Pagina 200

Chapter 9. IBM Systems Director Management Console management 2539.2.3 Testing network connectivityThe network connectivity can only be tested by u

Pagina 201

2 IBM Systems Director Management Console: Introduction and Overview1.1 Power Systems management consolesThe Hardware Management Console (HMC) allow

Pagina 202

254 IBM Systems Director Management Console: Introduction and OverviewBackupTo perform the backup, perform the following steps:1. Check if the system

Pagina 203 - (Figure 8-43)

Chapter 9. IBM Systems Director Management Console management 255Here is our example of this command:backup -l usb -Y6. The backup command starts th

Pagina 204

256 IBM Systems Director Management Console: Introduction and Overview-l The location to store the backup file. If sftp is specified, the -s argumen

Pagina 205

Chapter 9. IBM Systems Director Management Console management 2572. Select the virtual machine which want to back up, right-click it, and select Sna

Pagina 206

258 IBM Systems Director Management Console: Introduction and Overview3. Enter the snapshot name and description, and create a new snapshot of the se

Pagina 207

Chapter 9. IBM Systems Director Management Console management 2594. The snapshot is stored on the host. To copy it to another reliable location, sel

Pagina 208 - 8.4.2 Current Configuration

260 IBM Systems Director Management Console: Introduction and OverviewSteps for restore using the VMware vSphere ClientTo perform a restore using the

Pagina 209 - (Figure 8-48)

Chapter 9. IBM Systems Director Management Console management 2613. You can also select to restore from other snapshots by selecting the Snapshot Ma

Pagina 210

262 IBM Systems Director Management Console: Introduction and OverviewKVM backup procedureThe SDMC software appliance back up on KVM requires LVM sup

Pagina 211

Chapter 9. IBM Systems Director Management Console management 26311.Create the SDMC /Snapshot_LV_Dir/sdmc/data/images directory by running the follo

Pagina 212

Chapter 1. Overview 3The characteristics of those management consoles are as follows:򐂰 Hardware Management Console:– Is implemented as an external,

Pagina 213

264 IBM Systems Director Management Console: Introduction and Overviewlsrm -rf *4. Extract the tarball to the images directory and time it by running

Pagina 214 - 8.4.4 Server Profiles

Chapter 9. IBM Systems Director Management Console management 265/var/hsc/log/iqzdtrac.trm This log files contains information related to Common Con

Pagina 215

266 IBM Systems Director Management Console: Introduction and OverviewTrace logs in GUIYou can view the trace logs of the SDMC using the graphical us

Pagina 216

Chapter 9. IBM Systems Director Management Console management 2679.4.2 IBM Systems Director logsThe log files related to IBM Systems Director are l

Pagina 217

268 IBM Systems Director Management Console: Introduction and OverviewSDMC allows you to configure the settings for the trace and error logs. This ta

Pagina 218 - 8.5 Suspend and resume

Chapter 9. IBM Systems Director Management Console management 269Here are the available trace levels:򐂰 Severe򐂰 Warning򐂰 Info򐂰 Fine򐂰 Finer򐂰 FinestBy

Pagina 219 - (Figure 8-58)

270 IBM Systems Director Management Console: Introduction and OverviewThe usage of the pedbg command is as follows:pedbg [ -d [on | off] | -c | [-c &

Pagina 220

Chapter 9. IBM Systems Director Management Console management 271Run the lsconfig -v command to obtain the UVMID:sysadmin@dd174:~> lsconfig -vvpd

Pagina 221 - 8.6 Mobility

272 IBM Systems Director Management Console: Introduction and OverviewThere are three types of SDMC appliance updates:򐂰 Service pack updates򐂰 Interim

Pagina 222 - Figure 8-61 Click Validate

Chapter 9. IBM Systems Director Management Console management 273To auto-check and download applicable updates (which is easiest if the SDMC has acc

Pagina 223

IBM Systems Director Management Console: Introduction and OverviewApril 2011International Technical Support OrganizationSG24-7860-00

Pagina 224

4 IBM Systems Director Management Console: Introduction and OverviewSee Figure 1-2 for an overview of how the SDMC is placed in an enterprise-wide ad

Pagina 225 - HMC tasks

274 IBM Systems Director Management Console: Introduction and OverviewIf the SDMC does not have access to the internet, the manual procedures for ins

Pagina 226

© Copyright IBM Corp. 2011. All rights reserved. 275Chapter 10. Command-line interfaceThis chapter discusses the command-line interface (CLI) of the I

Pagina 227

276 IBM Systems Director Management Console: Introduction and Overview10.1 SDMC command-line interfaceIn the SDMC CLI there are three types of comma

Pagina 228 - User groups

Chapter 10. Command-line interface 277Table 10-1 provides a listing of the most important IBM Systems Director appliance commands and their usage. F

Pagina 229

278 IBM Systems Director Management Console: Introduction and Overview10.1.2 IBM Systems Director application commandsThe IBM Systems Director appli

Pagina 230

Chapter 10. Command-line interface 279Availability/mkvsmfarmAvailability/mkvsmmigratetaskLEDCLI/chledLEDCLI/lsledauditing/chauditauditing/lsauditAs

Pagina 231

280 IBM Systems Director Management Console: Introduction and Overview10.1.3 Power Systems management commandsThe Power Systems management (psm) com

Pagina 232 - Creating a role

Chapter 10. Command-line interface 281psm/chledpsm/chlparstatepsm/chlparutilpsm/chpwrmgmtpsm/chstatpsm/chsvcpsm/chsyscfgpsm/chsyspwdpsm/chsysstateps

Pagina 233

282 IBM Systems Director Management Console: Introduction and OverviewThe output of the Power Systems management commands on the SDMC is the same as

Pagina 234

Chapter 10. Command-line interface 283bkprofdata Backs up profile data for the managed system.The -o option will be ignored by SDMC.chcod Performs C

Pagina 235

Chapter 1. Overview 5See Figure 1-3 for a schematic overview. This figure shows where the SDMC fits into the overall view of IBM Systems Director sy

Pagina 236 - Deleting a role

284 IBM Systems Director Management Console: Introduction and Overviewcpdump Copies managed system dumps and managed frame dumps from the SDMC to DVD

Pagina 237

Chapter 10. Command-line interface 285lslock Lists which SDMC owns the lock on the managed frame.No change.lslparmigr Lists partition migration info

Pagina 238 - Creating a group

286 IBM Systems Director Management Console: Introduction and Overviewlsvet Lists Capacity on Demand advanced functions activation information for th

Pagina 239 - (Figure 9-8)

Chapter 10. Command-line interface 28710.3 HMC commands not supported on the SDMCTable 10-4 lists the HMC commands listed that are no longer suppor

Pagina 240

288 IBM Systems Director Management Console: Introduction and Overviewchaccfg smcli chrole. chhmc chnetcfg. chhmcencr No replacement available.chhmcf

Pagina 241

© Copyright IBM Corp. 2011. All rights reserved. 289Chapter 11. Schedule operationsIn this chapter, we describe how to schedule operations for certain

Pagina 242

290 IBM Systems Director Management Console: Introduction and Overview11.1 Scheduling operations for managed systems and Virtual ServersTo schedule

Pagina 243

Chapter 11. Schedule operations 291򐂰 Power On򐂰 Manage Utility CoD򐂰 Modify Shared Processor Pool򐂰 Modify Virtual Server Pool Assignment򐂰 Modify Power

Pagina 244 - Groups page (Figure 9-13)

292 IBM Systems Director Management Console: Introduction and OverviewClick OK, and the Task Launch Dialog page opens (Figure 11-3).Figure 11-3 Tas

Pagina 245

Chapter 11. Schedule operations 293Monthly You can specify the duration of how long the job repeats, if the job should run on weekends, and on which

Pagina 246 - Roles page (Figure 9-15)

6 IBM Systems Director Management Console: Introduction and Overview1.3 IVM, HMC, and SDMC supportThe transition will begin in the second half of 20

Pagina 247

294 IBM Systems Director Management Console: Introduction and Overview11.1.4 Creating the jobWhen you have made your selections in the Task Launch D

Pagina 248

Chapter 11. Schedule operations 295Figure 11-5 shows an overview over the scheduled, active, and completed jobs.Figure 11-5 Active and Schedule Jo

Pagina 249 - 9.1.5 User management

296 IBM Systems Director Management Console: Introduction and OverviewIf you click a job, you can view the properties of the selected job (Figure 11-

Pagina 250 - Local authentication

Chapter 11. Schedule operations 29711.3 Automation ManagerIf you select the Automation Manager on the main Manage tab, you get an overview over the

Pagina 251

298 IBM Systems Director Management Console: Introduction and Overview

Pagina 252

© Copyright IBM Corp. 2011. All rights reserved. 299Chapter 12. High availability and redundancyImplementing IBM Systems Director Management Console (

Pagina 253

300 IBM Systems Director Management Console: Introduction and Overview12.1 Systems Director Management Console High Availability versus redundant se

Pagina 254

Chapter 12. High availability and redundancy 301򐂰 For an environment where the SDMC is used for agent OS management and there is a high availability

Pagina 255

302 IBM Systems Director Management Console: Introduction and OverviewFor this setup, configure an SDMC (A) to point to the active agent manager runn

Pagina 256

Chapter 12. High availability and redundancy 303Figure 12-3 shows both the software and hardware stack that of an SDMC High Availability environment

Pagina 257

Chapter 1. Overview 7This support plan is the same plan as the support plan for the Hardware Management Console. For proper and supported function,

Pagina 258 - Kerberos

304 IBM Systems Director Management Console: Introduction and OverviewRunning the setup wizard or using CLI commands on the SDMC designated to be the

Pagina 259

Chapter 12. High availability and redundancy 305Primary node This is the node you use to set up high availability. It is initially the active node.

Pagina 260

306 IBM Systems Director Management Console: Introduction and Overview12.2.3 SDMC High Availability processes monitoredThese are the processes monit

Pagina 261

Chapter 12. High availability and redundancy 30712.3 Active/Passive High Availability: Configuration planningYou need to plan the setup of SDMC Hig

Pagina 262

308 IBM Systems Director Management Console: Introduction and Overview12.3.1 Network requirementsBecause data is continually replicated between the

Pagina 263 - Modifying user properties

Chapter 12. High availability and redundancy 309Replication IP addressBecause the replication IP address on each of the two SDMC nodes in the High A

Pagina 264

310 IBM Systems Director Management Console: Introduction and Overview򐂰 Choose an address that each node can reach by a single path. If there are mul

Pagina 265

Chapter 12. High availability and redundancy 31112.3.2 DHCP considerationsThe SDMC cannot be a DHCP client. If your network is set up so that one D

Pagina 266 - 9.2 Network configuration

312 IBM Systems Director Management Console: Introduction and OverviewShared DHCP configurationThe DHCP server is only run on the active node. Config

Pagina 267

Chapter 12. High availability and redundancy 31312.4.1 Configuration using SDMC High Availability setup wizardPerform the following steps:1. Open u

Pagina 268

8 IBM Systems Director Management Console: Introduction and OverviewThe virtualization layer for the hardware appliance is fixed and cannot be change

Pagina 269 - LAN adapter

314 IBM Systems Director Management Console: Introduction and Overview2. The Welcome page for the High Availability setup wizard (Figure 12-8) shows

Pagina 270 - Figure 9-31 DHCP server

Chapter 12. High availability and redundancy 3153. In the Secondary Node setup page (Figure 12-9), enter the IP address or host name and the passwor

Pagina 271 - IP address

316 IBM Systems Director Management Console: Introduction and Overview5. In the Replication IP Address page (Figure 12-10), specify the IP addresses

Pagina 272 - Firewall

Chapter 12. High availability and redundancy 3176. If you want a network status IP address, determine an appropriate IP address and enter it into th

Pagina 273

318 IBM Systems Director Management Console: Introduction and Overview7. Determine the available IP address to be used as the floating IP address and

Pagina 274 - Host and gateway

Chapter 12. High availability and redundancy 3198. If you use Systems Director Common Agent Services, you must specify an agent manager IP address s

Pagina 275 - Figure 9-34 DNS menu

320 IBM Systems Director Management Console: Introduction and Overview9. The final page (Figure 12-14) shows the summary of all the configuration inp

Pagina 276 - Network reconfiguration

Chapter 12. High availability and redundancy 321After the configuration completes, you can use the floating IP address to connect to the Systems Dir

Pagina 277

322 IBM Systems Director Management Console: Introduction and Overview12.5 Active/Passive High Availability: UpdatesFor the initial release of the S

Pagina 278 - Changing network settings

Chapter 12. High availability and redundancy 323The Director data is at a Snapshot level that is equivalent to when you started the upgrade. Events

Pagina 279 - 9.3 Backup and restore

Chapter 1. Overview 9Table 1-2 POWER6 support by SDMCTable 1-3 POWER7 support by SDMCPOWER6 models Machine types SDMC595 9119-FHA HW APP Only575

Pagina 280

324 IBM Systems Director Management Console: Introduction and Overview

Pagina 281

© Copyright IBM Corp. 2011. All rights reserved. 325Chapter 13. Advanced System Management InterfaceIn this chapter, we describe how to log in to the

Pagina 282

326 IBM Systems Director Management Console: Introduction and Overview13.1 Connecting to ASMI using the SDMCTo connect to the ASMI using the SDMC, p

Pagina 283

Chapter 13. Advanced System Management Interface 3273. A page opens that has a drop-down menu for the service processor to which you want to connect

Pagina 284

328 IBM Systems Director Management Console: Introduction and Overview4. A new browser page opens with the login page of the ASMI (Figure 13-3).Figur

Pagina 285

Chapter 13. Advanced System Management Interface 32913.2 Connecting to ASMI using the CLITo connect to the ASMI using the SDMC command-line interfa

Pagina 286

330 IBM Systems Director Management Console: Introduction and OverviewSystem Dump Initiates a system dump.Service Processor Dump Initiates a service

Pagina 287

Chapter 13. Advanced System Management Interface 331Memory Serial Presence Detect DataShows manufactures data of detected memory modules.Firmware Ma

Pagina 288 - KVM backup procedure

332 IBM Systems Director Management Console: Introduction and OverviewSelective Memory MirroringThis function is not available when your system is co

Pagina 289 - Restoring on KVM

Chapter 13. Advanced System Management Interface 333򐂰 Network ServicesNetwork Configuration Displays and modifies the network configuration of the s

Pagina 290 - 9.4 Problem determination

10 IBM Systems Director Management Console: Introduction and Overview1.5 TerminologyBased on the integration into IBM Systems Director, a common ter

Pagina 291

334 IBM Systems Director Management Console: Introduction and Overview򐂰 Login ProfileChange Password Lets you change the general user, administrator,

Pagina 292 - Trace logs in GUI

© Copyright IBM Corp. 2011. All rights reserved. 335Chapter 14. Service and supportThis chapter provides information about the service and support fea

Pagina 293

336 IBM Systems Director Management Console: Introduction and Overview14.1 IntroductionService and Support Manager (SSM) is part of IBM Systems Dire

Pagina 294

Chapter 14. Service and support 33714.2 Setup wizardTo set up the Service and Support Manager to report serviceable problems to IBM, you have to ru

Pagina 295 - 9.4.4 Using pedbg

338 IBM Systems Director Management Console: Introduction and OverviewPerform the following steps:1. Click the Service and Support Manager Getting St

Pagina 296 - 9.4.5 Using pesh

Chapter 14. Service and support 3392. On the next page, enter your company’s contact data (Figure 14-3).Figure 14-3 Company contact page

Pagina 297 - 9.5 SDMC appliance update

340 IBM Systems Director Management Console: Introduction and Overview3. The fields marked by an asterisk are mandatory and must be completed before

Pagina 298

Chapter 14. Service and support 3415. In the Connection page, you have to specify how the SDMC can connect to IBM, either through a direct Internet

Pagina 299

342 IBM Systems Director Management Console: Introduction and Overview6. When you click Next, the Authorize IBM IDs page opens (Figure 14-6).Figure 1

Pagina 300

Chapter 14. Service and support 3437. When you click Next, the Summary page opens (Figure 14-7).Figure 14-7 Summary page8. You can always go back

Pagina 301 - Command-line interface

Chapter 1. Overview 11The command-line interface has been mostly kept the same. On the SDMC, most of the commands are just preceded by smcli. This n

Pagina 302

344 IBM Systems Director Management Console: Introduction and OverviewThe tasks related to the Call Home feature are available on the context menu of

Pagina 303

Chapter 14. Service and support 345Support FilesYou can use this task to collect the support files for the monitored system. The support files can b

Pagina 304

346 IBM Systems Director Management Console: Introduction and Overview14.4 Serviceable event processingThe Service and Support Manager automatically

Pagina 305

Chapter 14. Service and support 34714.4.2 Persistent storage and management of serviceable event dataService and Support Manager persists all the i

Pagina 306

348 IBM Systems Director Management Console: Introduction and Overview14.4.5 User actionsYou can see a problems dashboard on top of the web interfac

Pagina 307

Chapter 14. Service and support 349This page shows all the active problems reported for all discovered systems. Click any of the problems and you sh

Pagina 308

350 IBM Systems Director Management Console: Introduction and OverviewThe General tab provides information from the Director Status Set of the event.

Pagina 309

Chapter 14. Service and support 351You can also close a serviceable event by selecting Request Closure of a given service request, which causes the

Pagina 310

352 IBM Systems Director Management Console: Introduction and OverviewSystem wide support files viewThe system wide support files view can be reached

Pagina 311

Chapter 14. Service and support 353After you click the link, the Manage Support Files system wide view opens (Figure 14-14).Figure 14-14 Manage Su

Pagina 312

12 IBM Systems Director Management Console: Introduction and Overview1.6.3 Additional functionsThe SDMC comes with the IBM Systems Director base man

Pagina 313

354 IBM Systems Director Management Console: Introduction and OverviewMonitored system support files viewThe monitored system support files view can

Pagina 314

Chapter 14. Service and support 355Serviceable problem support files viewThe serviceable problem support files view can be reached over an active se

Pagina 315 - Schedule operations

356 IBM Systems Director Management Console: Introduction and Overview򐂰 Submit support files to IBM by clicking the Submit to IBM... button, or by us

Pagina 316 - Virtual Servers

Chapter 14. Service and support 357Figure 14-17 Collect Support Files pageYou can only get support files from one system at a time. Specify the ty

Pagina 317

358 IBM Systems Director Management Console: Introduction and OverviewSystem dump A system dump is a dump of the hardware and server firmware content

Pagina 318 - 11.1.1 Schedule tab

Chapter 14. Service and support 359There are two other tasks that can be used to remove support files򐂰 The Service and Support Manager Support File

Pagina 319 - 11.1.3 Options

360 IBM Systems Director Management Console: Introduction and OverviewProperties of support filesOn the General tab of the properties page of a suppo

Pagina 320 - 11.1.4 Creating the job

Chapter 14. Service and support 361򐂰 You can see the location where the support files are saved locally.򐂰 You can see the free space left for the su

Pagina 321

362 IBM Systems Director Management Console: Introduction and Overview14.6 Service and Support Manager command-line interfaceThe Service and Support

Pagina 322 - Figure 11-7 Log of the job

Chapter 14. Service and support 36314.7 Service and Support Manager tasksThe Service and Support Manger (SSM) defines a number of tasks (scheduled

Pagina 323 - 11.3 Automation Manager

Chapter 1. Overview 131.6.7 SDMC considerationsHere is the list of limitations for SDMC when compared with the HMC:򐂰 The system plans feature is no

Pagina 324

364 IBM Systems Director Management Console: Introduction and Overview򐂰 Collect Performance DataThis task runs on a daily basis. It is performed for

Pagina 325 - High availability and

Chapter 14. Service and support 36514.9 Guided RepairYou can perform Guided Repair procedures from the context menu of a managed system. Right-clic

Pagina 326

366 IBM Systems Director Management Console: Introduction and OverviewProblem Repair You can execute a repair from the Problem Information page, whic

Pagina 327

© Copyright IBM Corp. 2011. All rights reserved. 367Appendix A. Command-line referenceIn this appendix, we list the IBM Systems Director Management Co

Pagina 328

368 IBM Systems Director Management Console: Introduction and OverviewIBM Power Systems management commandsThis section lists the Power Systems manag

Pagina 329 - Post-Failover

Appendix A. Command-line reference 369Table A-3 shows information about the mk5250 command.Table A-3 mk5250 commandTable A-4 shows information abo

Pagina 330

370 IBM Systems Director Management Console: Introduction and OverviewIBM Systems Director application commandsThis section lists the IBM Systems Dir

Pagina 331

Appendix A. Command-line reference 371Event commandsThis section lists the commands for event handling. To see the options of the commands in the ev

Pagina 332

372 IBM Systems Director Management Console: Introduction and OverviewTable A-10 shows information about the listeventactions command.Table A-10 li

Pagina 333

Appendix A. Command-line reference 373Table A-13 shows information about the listfilters command.Table A-13 listfilters commandScheduler commandsI

Pagina 334 - 12.3.1 Network requirements

© Copyright International Business Machines Corporation 2011. All rights reserved.Note to U.S. Government Users Restricted Rights -- Use, duplication

Pagina 335 - Network status IP address

14 IBM Systems Director Management Console: Introduction and Overview

Pagina 336

374 IBM Systems Director Management Console: Introduction and OverviewTable A-16 shows information about the getjobstatus command.Table A-16 getjob

Pagina 337 - 12.3.2 DHCP considerations

Appendix A. Command-line reference 375SSM commandsIn this section, we list the commands for the Service and Support Manager (SSM).Table A-20 shows i

Pagina 338 - Shared DHCP configuration

376 IBM Systems Director Management Console: Introduction and OverviewTable A-22 shows information about the cpsptfile command.Table A-22 cpsptfile

Pagina 339

Appendix A. Command-line reference 377Table A-23 shows information about the lssptfile command.Table A-23 lssptfile commandCommand lssptfileDefini

Pagina 340 - Figure 12-8 Welcome page

378 IBM Systems Director Management Console: Introduction and OverviewTable A-24 shows information about the lssvcproblem command.Table A-24 lssvcp

Pagina 341

Appendix A. Command-line reference 379Table A-26 shows information about the ssmimport command.Table A-26 ssmimport commandExample This example il

Pagina 342

380 IBM Systems Director Management Console: Introduction and OverviewTable A-27 shows information about the submitsptfile command.Table A-27 submi

Pagina 343

Appendix A. Command-line reference 381Syntax smcli configureHA--secondary-node secNode--password thePassword--primary-rep-addr primRepAddr--secondar

Pagina 344

382 IBM Systems Director Management Console: Introduction and OverviewTable A-29 shows information about the failover command.Table A-29 failover c

Pagina 345 - Click Next

Appendix A. Command-line reference 383Table A-30 shows information about the removeHA command.Table A-30 removeHA commandUser commandsIn this sect

Pagina 346 - Figure 12-14 Summary page

© Copyright IBM Corp. 2011. All rights reserved. 15Chapter 2. InstallationIn this chapter, we describe the installation of the IBM Systems Director Ma

Pagina 347 - Additional command-line tools

384 IBM Systems Director Management Console: Introduction and OverviewTable A-32 shows information about the rmuser command.Table A-32 rmuser comma

Pagina 348

Appendix A. Command-line reference 385Other commandsIn this section, we list commands not listed in the previous sections.Table A-33 shows informati

Pagina 349

386 IBM Systems Director Management Console: Introduction and OverviewTable A-35 shows information about the licensestatus command.Table A-35 licen

Pagina 350

Appendix A. Command-line reference 387Table A-39 shows information about the startdiscovery command.Table A-39 startdiscovery commandTable A-40 sh

Pagina 351 - Management Interface

388 IBM Systems Director Management Console: Introduction and Overview

Pagina 352

© Copyright IBM Corp. 2011. All rights reserved. 389Appendix B. IBM Systems Director base functionsIn this appendix, we discuss the IBM Systems Direct

Pagina 353

390 IBM Systems Director Management Console: Introduction and OverviewBase functionsBase functions (plug-ins) in IBM Systems Director provide core fu

Pagina 354 - Figure 13-3 ASMI login

Appendix B. IBM Systems Director base functions 391Configuration ManagerThe Configuration Manager is used to integrate new hardware into your enviro

Pagina 355 - 13.3 Using ASMI

392 IBM Systems Director Management Console: Introduction and OverviewIBM Power Systems managementIBM Power Systems management provides life cycle ma

Pagina 356

© Copyright IBM Corp. 2011. All rights reserved. 393Appendix C. IBM Systems Director Management Console distribution detailsIn this appendix, we give

Pagina 357

16 IBM Systems Director Management Console: Introduction and Overview2.1 PrerequisitesThis section lists the requirements and pre-requisites for the

Pagina 358

394 IBM Systems Director Management Console: Introduction and OverviewIBM Systems Director Management Console virtual disk imagesTable C-1 shows the

Pagina 359

© Copyright IBM Corp. 2011. All rights reserved. 395AME Active Memory ExpansionAMM Advanced Management ModuleAMS Active Memory SharingASM Advanced Sy

Pagina 360

396 IBM Systems Director Management Console: Introduction and OverviewSMS Systems Management ServicesSPCN System Power Control NetworkSSH Secure Shel

Pagina 361 - Service and support

© Copyright IBM Corp. 2011. All rights reserved. 397Related publicationsThe publications listed in this section are considered particularly suitable f

Pagina 362 - 14.1 Introduction

398 IBM Systems Director Management Console: Introduction and Overview򐂰 IBM Fix Centralhttp://www.ibm.com/support/fixcentral/򐂰 IBM Systems Director 6

Pagina 363 - 14.2 Setup wizard

© Copyright IBM Corp. 2011. All rights reserved. 399IndexNumerics7042-CR6 16–17Aaccesssys command 82activate Virtual Server 152Active and Sched

Pagina 364 - Perform the following steps:

400 IBM Systems Director Management Console: Introduction and Overviewfailover 321impdata 68, 282lsbundle 278lsldap 228lsled 59lsnetcfg 2

Pagina 365

Index 401configuration 246First Failure Data Capture (FFDC) 364Flexible Service Processor (FSP) 308failover 365floating IP address 303, 30

Pagina 366

402 IBM Systems Director Management Console: Introduction and Overviewstates 10LPAR See logical partitionlsbundle command 278lsldap command 228

Pagina 367 - Figure 14-5 Connection page

Index 403rediscover command 83redundancy 12, 299–301relocation 10Remote Access Manager 391Remote Command Execution 276Remote Monitoring an

Pagina 368

Chapter 2. Installation 17The supported host operating systems and hypervisors are:򐂰 Red Hat Enterprise Linux (RHEL) 5.5 with KVM (kvm-83-164.el5) o

Pagina 369 - 14.3 Call Home

404 IBM Systems Director Management Console: Introduction and Overviewsmhastatus command 320–321SMManager role 10, 199, 205smmgr group 202smmon

Pagina 370

Index 405Xx86 hardware 16–17

Pagina 371

406 IBM Systems Director Management Console: Introduction and Overview

Pagina 372

(0.5” spine)0.475”<->0.875”250 <-> 459 pagesIBM Systems Director Management Console: Introduction and Overview

Pagina 375

®SG24-7860-00 ISBN 0738435449INTERNATIONAL TECHNICALSUPPORTORGANIZATIONBUILDING TECHNICALINFORMATION BASED ONPRACTICAL EXPERIENCE IBM Redbooks are dev

Pagina 376

18 IBM Systems Director Management Console: Introduction and Overview2.2.1 Hardware installationFor the hardware appliance, you need at least one ne

Pagina 377 - 14.5.1 Support Files view

Chapter 2. Installation 192. After DVD1 is copied, the following prompt appears:Press Enter to shutdown the system. After the system is powered off,

Pagina 378 - Tasks (Figure 14-13)

20 IBM Systems Director Management Console: Introduction and Overview򐂰 A graphical interface on the VMWare Virtual Infrastructure ClientTo use the CL

Pagina 379 - (Figure 14-14)

Chapter 2. Installation 212. Select File  Deploy OVF Template, as shown in Figure 2-2.Figure 2-2 Deploy OVF Template from vSphere Client

Pagina 380

22 IBM Systems Director Management Console: Introduction and Overview3. Select the Deploy from file radio button and click the Browse button. Navigat

Pagina 381

Chapter 2. Installation 234. Continue through the pages until you reach the Ready to Complete page. Review the deployment settings and click Finish

Pagina 382

© Copyright IBM Corp. 2011. All rights reserved. iiiContentsFigures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 383

24 IBM Systems Director Management Console: Introduction and Overview2. Because all files and images needed are contained within the OVA, you can sim

Pagina 384 - Deleting support files

Chapter 2. Installation 25This command extract the disk images (dvmdisk1.img, dvmdisk2.img, dvmdisk3.img,...dvmdisk7.img).4. Create the domain XML f

Pagina 385

26 IBM Systems Director Management Console: Introduction and OverviewSee the sample domain.xml file in Example 2-2. The tags that might have to be cu

Pagina 386 - Properties of support files

Chapter 2. Installation 27 </disk> <disk type="file" device="disk"> <source file="/vdisk1/vm1/dvm

Pagina 387 - Dump settings

28 IBM Systems Director Management Console: Introduction and Overview5. Define VM by running the following command:virsh define <domain>.xml6.

Pagina 388

Chapter 2. Installation 29– pt_br: Brazilian Portuguese– zh_CN: Simplified Chinese– zh_TW: Traditional Chinese2. Accept the IBM Software License Agr

Pagina 389

30 IBM Systems Director Management Console: Introduction and Overview3. After accepting the license agreement, the Welcome page of the setup wizard o

Pagina 390

Chapter 2. Installation 314. Enter the date, time, and time zone for your location (Figure 2-8).Figure 2-8 Date and Time page

Pagina 391 - 14.9 Guided Repair

32 IBM Systems Director Management Console: Introduction and Overview5. The next four pages request the passwords for the sysadmin, root, and pe user

Pagina 392 - 14.9.1 Differences from HMC

Chapter 2. Installation 33square brackets ([ ]), backslash (\), colon (:), quotation mark ("), semicolon (;), and apostrophe ('). – Passwo

Pagina 393 - Command-line reference

iv IBM Systems Director Management Console: Introduction and Overview2.3.2 VMware installation . . . . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 394

34 IBM Systems Director Management Console: Introduction and Overview8. The last page to complete is the Agent Manager configuration page (Figure 2-1

Pagina 395

Chapter 2. Installation 359. After completing the last page and clicking Next, the Summary page opens (Figure 2-12). You can always go back from her

Pagina 396

36 IBM Systems Director Management Console: Introduction and Overview10.If all went well, you see the System Setup Processing page; a status of Succe

Pagina 397 - Event commands

Chapter 2. Installation 3711.After clicking Close, the SDMC boots and a startup page opens (Figure 2-14).Figure 2-14 Console starting page

Pagina 398

38 IBM Systems Director Management Console: Introduction and OverviewThe startup takes up to five minutes. When the startup is finished, the Systems

Pagina 399 - Scheduler commands

Chapter 2. Installation 392.5.1 SDMC hardware applianceFor the SDMC hardware appliance, the customer needs to order the 7042-CR6 machine type with

Pagina 400

40 IBM Systems Director Management Console: Introduction and Overview

Pagina 401 - SSM commands

© Copyright IBM Corp. 2011. All rights reserved. 41Chapter 3. Basic operationThis chapter provides an overview of features and tasks provided by IBM S

Pagina 402

42 IBM Systems Director Management Console: Introduction and Overview3.1 Features overviewThe SDMC is now available as part of the IBM Systems Direc

Pagina 403

Chapter 3. Basic operation 43Edit host This task displays the properties of the server. The properties contain information about the processors, mem

Pagina 404

Contents v5.1.1 System discovery functions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 765.1.2 Discovery of POWER processor-bas

Pagina 405

44 IBM Systems Director Management Console: Introduction and OverviewCollect utilization dataYou can set the SDMC to collect the resource utilization

Pagina 406 - High availability commands

Chapter 3. Basic operation 45Suspend and resume Virtual ServersYou can suspend Virtual Servers to store its state on a Storage Area Network (SAN). Y

Pagina 407

46 IBM Systems Director Management Console: Introduction and OverviewRebuild Power Unit Use this task to rebuild the Power Unit information in the SD

Pagina 408

Chapter 3. Basic operation 47Security and user managementYou can create users and roles. You can assign permissions to roles and assign the roles to

Pagina 409 - User commands

48 IBM Systems Director Management Console: Introduction and OverviewSupport file managementSSM provides the following capabilities for managing supp

Pagina 410

Chapter 3. Basic operation 493.2 Using the web interfaceSDMC provides a web interface similar to the HMC. Power on the SDMC appliance and you shoul

Pagina 411 - Other commands

50 IBM Systems Director Management Console: Introduction and OverviewEnter the user ID and password that corresponds to an authorized SDMC user and c

Pagina 412

Chapter 3. Basic operation 51There could be other non-Power Systems that are discovered and managed by SDMC. You can see these systems in the Naviga

Pagina 413

52 IBM Systems Director Management Console: Introduction and OverviewYou can open multiple views or pages and have them open as tabs at the same time

Pagina 414

Chapter 3. Basic operation 53Figure 3-3 shows a snapshot of the layout of the management tasks on the context menu of the server.Figure 3-3 Contex

Pagina 415 - IBM Systems Director base

vi IBM Systems Director Management Console: Introduction and Overview8.2 Virtual Server activation . . . . . . . . . . . . . . . . . . . . . . . .

Pagina 416 - Base functions

54 IBM Systems Director Management Console: Introduction and OverviewFigure 3-4 shows the other tasks that are available in the context menu of the s

Pagina 417

Chapter 3. Basic operation 55Figure 3-5 shows a snapshot of the layout of the management tasks available on the context menu of the Virtual Server.F

Pagina 418

56 IBM Systems Director Management Console: Introduction and OverviewTable viewThe table view displays a list of resources along with their informati

Pagina 419

Chapter 3. Basic operation 57Properties viewThe properties view displays a list of properties and other detailed information related to the selected

Pagina 420

58 IBM Systems Director Management Console: Introduction and OverviewTopology viewThe topology view displays the relationship among your resources. S

Pagina 421 - Abbreviations and acronyms

Chapter 3. Basic operation 593.3 Command-line interfaceThe IBM Systems Director provides the systems management command-line interface, referred to

Pagina 422

60 IBM Systems Director Management Console: Introduction and Overview

Pagina 423 - Related publications

© Copyright IBM Corp. 2011. All rights reserved. 61Chapter 4. Making the transition to the IBM Systems Director Management ConsoleThis chapter describ

Pagina 424 - Help from IBM

62 IBM Systems Director Management Console: Introduction and Overview4.1 ConceptsTransition is a new feature that is available to transition systems

Pagina 425 - Numerics

Chapter 4. Making the transition to the IBM Systems Director Management Console 634.2.1 What is transitionedWhen you transition managed systems fro

Pagina 426

Contents vii11.1 Scheduling operations for managed systems and Virtual Servers . . . . 29011.1.1 Schedule tab . . . . . . . . . . . . . . . . . .

Pagina 427

64 IBM Systems Director Management Console: Introduction and Overview򐂰 Creates default profiles based on Virtual Server current configuration read fr

Pagina 428

Chapter 4. Making the transition to the IBM Systems Director Management Console 654.3 HMC to SDMC transitionThis section describes how you can tran

Pagina 429

66 IBM Systems Director Management Console: Introduction and OverviewPerform the following steps to perform an online transition:1. Launch the transi

Pagina 430

Chapter 4. Making the transition to the IBM Systems Director Management Console 674. You should now see a list of managed systems (Figure 4-2) that

Pagina 431

68 IBM Systems Director Management Console: Introduction and OverviewAfter successful authentication, the Access state of the managed system changes

Pagina 432

Chapter 4. Making the transition to the IBM Systems Director Management Console 69All serviceable events must be closed before you can execute this

Pagina 433

70 IBM Systems Director Management Console: Introduction and Overview5. Browse to and select the exported configuration data file from step 1 (Figure

Pagina 434

Chapter 4. Making the transition to the IBM Systems Director Management Console 714.3.6 Offline transition using the command-line interfacePerform

Pagina 435

72 IBM Systems Director Management Console: Introduction and OverviewThe flow chart in Figure 4-4 shows a snapshot of the complete transition process

Pagina 436

Chapter 4. Making the transition to the IBM Systems Director Management Console 734.4.1 SDMC as the DHCP serverPerform the following steps to perfo

Commenti su questo manuale

Nessun commento